banner
PRODUCTS

SynGenX®-LAB System

For isolating cell populations from bone marrow,
blood or apheresis products

  • XLab -1
  • XLab -2
  • XLab -3
  • XLab -4
  • XLab -5
1 2 3 4 5
 

SynGenX®-LAB System
SynGenX®-LAB Disposable Cartridge
SynGenX®-LAB Control Module
SynGenX®-LAB Docking Station
SynGenX® DataTrak Software

SynGenX®-LAB System

The SynGenX®-LAB System* is designed for the efficient extraction of target cell populations from bone marrow, blood or apheresis products in a closed device, and is intended for use in cell processing laboratories.

The SynGenX-LAB System automatically harvests the target cell population from a sample during a short cycle on a programmable bench top centrifuge without the use of Ficoll.

In addition, the System’s firmware and DataTrak software generate a report of the entire centrifugation and harvest process, and download it  to your host PC for cGLP compliance.

The SynGenX®-LAB system is available in the US, and commercial release in the European Union is pending. Contact sales@syngeninc.com for more details.

The system is considered general laboratory equipment.

 

Key Features:

  • Highly efficient recoveries and/or depletions of target cell populations automatically, without the use of Ficoll.
  • 15 to 30 minute processing time
  • Easy to Use

The Components of the System are:

  • SynGenX®-LAB Disposable Cartridge
  • SynGenX®-LAB Control Module
  • SynGenX®-LAB Docking Station
  • SynGen® DataTrak Software

XLab_DC_Proc_Side-1_v0814

The SynGenX®-LAB Disposable Cartridge

Each SynGenX®-LAB Disposable Cartridge processes a sample of bone marrow, blood or apheresis products with a volume between 40 mL to 220 mL.  The Disposable Cartridge has three discrete compartments for separation of the sample into a defined volume of the target cells, red blood cells and the remaining plasma.  The target cells are readily collected from the target cell harvest compartment via a pre-attached access tube, using a syringe.  Four disposable cartridges can be processed simultaneously, enabling nearly 1 liter of starting material to be processed.

XLab_CM_Std_FrontTop-01_v0514SynGenX®-LAB Control Module

The SynGenX®-LAB Control Module automatically directs the separation of the target cells, red cells and plasma into their respective chambers, by monitoring the  speed of the centrifuge, and opening and closing valves at the base of the Disposable Cartridge at the right times.

 

XLab_DS_Std_FrontSideTopAng-02_v0514

SynGenX®-LAB Docking Station

The SynGenX®-LAB Docking Station transfers the data collected during the centrifuge run by the Control Module to the host PC via the DataTrak software.  It also charges the Control Module’s lithium polymer ion battery.  A fully charged battery will allow the Control Module to operate up to 8 days.

1 - LoginSynGenX® DataTrak Software

The SynGen® DataTrak software is installed on the host’s PC and is the user interface for the SynGenX-Lab System.  The software allows the operator of the SynGenX-Lab System to use a bar code reader to track and record equipment serial numbers and disposable lot numbers.

 

The software also downloads performance data from the Control Module to the host PC that includes important cGLP information:

35 - Control Module Processing Report

Control Module Processing Report

•  Duration of periods at constant speeds and precise timing of the accelerations and decelerations of the centrifuge.

•  Opening and closing of the valves that direct target cells and red blood cells to their respective compartments at the base of the Disposable Cartridge.

•  Documentation of the successful completion of the processing cycle.

•  Space for sign-off of the data set by the lab director, if desired.

 

 

*The SynGenX®-LAB system is designed for the efficient isolation of cell populations from bone marrow or blood samples, and is classified as general laboratory equipment. 

XLab_DC_Proc_Side-1_v0414How It Works

 

The SynGenX®-LAB System is designed for the efficient extraction of target cell populations from bone marrow or blood samples in a closed device.

The sample is transferred to the central sample chamber of the SynGenX®-LAB Disposable Cartridge via transfer tubing through a 150 micron filter to remove any clots and bone chips.

XLab wCentrifuge

 

 

 

The Disposable Cartridge is latched onto the SynGenX®-LAB Control Module, placed in the centrifuge and counter balanced with a SynGen counterweight cartridge. During centrifugation, the sample is separated into three fractions:  red blood cells, target cells, and plasma.

 

XLab cartridge wLayers

The SynGen X-LAB Disposable Cartridge features a cone-shaped region at the bottom of the central sample chamber where the cell fractions of the sample stratify during centrifugation. Four vertically aligned, infrared sensor-pairs in the Control Module continuously monitor the region, detect cell fraction interfaces, and trigger opening and closing of the valves that direct the red blood cells and the target cells to their respective chambers.  This allows high precision separation and harvest of the target cells during processing.

XLab_CMDS_Std_Front_v0314

 

The SynGenX®-LAB Docking Station transfers the data collected during the centrifuge run by the Control Module via SynGen™ DataTrak software installed on a PC.

Resources

M-0040-C Peripheral Blood Mononuclear Cell Isolation Protocol.pdf

Results

 

Check Back – in progress!